HVAC ductwork (air ducts) carries air between the unit and the spaces it serves. Material and shape matter, but assessment also requires reviewing airflow, system resistance, joint sealing, insulation and inspection access.
This guide explains duct design, types and air distribution in ducted systems, including concealed AC. To assess whether the system itself suits your project, see the Concealed AC Guide Before Installation.
What is the difference between supply and return ducts?
Supply ducts carry air from the unit to the air outlets, while the return provides a path back to the unit. The return arrangement depends on the project design. Do not assume that each room has a separate return duct or that the ceiling void is automatically suitable as a return air path.
The designer reviews the supply and return layout and how doors and partitions affect air movement. The number and appearance of grilles alone do not demonstrate that each room receives the required airflow.
Duct types: Galvanised, pre-insulated, flexible and fabric
Start with the application, system location and performance requirements, then compare materials approved for the project. The following table sets out selection criteria rather than a fixed ranking:
| Type | What to check | Selection limits |
|---|---|---|
| Galvanised metal ductwork | A rigid system whose metal thickness, reinforcement, joints, supports and insulation requirements must be reviewed. | The material alone does not determine airtightness or noise. Joint quality and workmanship are part of the assessment. |
| Pre-insulated ductwork | A panel system with integrated insulation. Review product data, classifications, assembly methods and supports. | Do not assume that one product suits every pressure and location. Request documentation for the proposed system. |
| Flexible ductwork | Connections within the approved design, with controlled lengths, bends and support. | Sagging, compression and bends can change the cross-sectional area and airflow resistance. |
| Fabric ductwork | An air distribution solution for suitable applications, selected with a defined distribution pattern and suspension arrangement. | It does not, by itself, guarantee the removal of hot spots. Review the distribution design and product care requirements. |
Rectangular, round or spiral ductwork?
The shape depends on available space, airflow, pressure loss, support requirements and appearance. A rectangular section may help coordinate ceiling clearance, while a round duct requires checking its diameter and the space needed for its route. Spiral describes a common manufacturing method for round ducts, not a separate performance rating.
Compare sections by more than shape. Ask the designer for alternatives that deliver the required airflow, identifying route resistance, space and cost. Round ducts do not guarantee quiet operation, and rectangular ducts do not automatically cause noise.
Single or double? Understanding single-wall and double-wall ducts
If a quotation refers to single or double ductwork, request a section showing the construction: the number of walls, insulation type and position, and inner wall details where it is used for acoustic treatment. Distinguish wall construction from sheet metal thickness or the number of insulation layers.
Assess each option against thermal and acoustic requirements, space, weight and inspection arrangements. Double-wall ducts are not automatically necessary for every project, and single-wall construction does not automatically mean there is no insulation.
How are duct sizes and airflow calculated?
Sizing starts with the required airflow for each branch and route, rather than AC capacity in tons alone. Airflow is expressed in units such as CFM or litres per second. The designer checks air velocity and pressure losses through ducts, elbows, branches and other relevant components.
The simplified relationship is: Airflow = Cross-sectional area × Air velocity using compatible units. At a constant airflow, reducing the area increases velocity. In a real system, however, airflow itself may change with route resistance and fan performance.
Smaller ducts may increase resistance and noise or restrict airflow. Larger ducts do not inherently weaken air delivery, but may require more space and cost. The decision should follow system calculations and compatibility with the unit data rather than a rule that smaller or larger is always better.
If the unit has already been selected, request a review of the airflow and available external static pressure at the required operating point. Equipment selection has separate criteria, explained in the guide to comparing concealed AC brands and models.
Duct insulation and joint sealing serve different purposes
Thermal insulation limits heat transfer through the duct body, while sealing limits air leakage. Insulating a leaking system does not repair its leaks, and sealing does not replace insulation where the design requires it.
Insulation thickness, thermal resistance, vapour barrier and protective covering depend on site conditions and project requirements. Check continuity, seams and connections, especially where cold surfaces are in warm, humid spaces. No single insulation specification suits every location.
The US Department of Energy guidance on metal ducts explains the roles of insulation, vapour barriers and joint sealing. These principles help explain their functions; local project specifications must be established independently.
Air distribution and balancing with grilles
Assessment does not end when duct installation is complete. Check outlet airflow against design values and adjust the balancing devices to suit the system. Increasing airflow in one branch may affect others, so a larger grille or higher fan speed is not always the answer.
Outlet type, position and air direction are explained separately in the AC grilles guide. To investigate noise or uneven temperatures after commissioning, see the concealed AC troubleshooting guide; these symptoms may have several causes.
What should you check before closing the ceiling?
- Routes, sizes and materials match the approved drawings and specifications.
- Supports, reinforcement, joints and their protection are checked, and the system is sealed before areas requiring inspection are covered.
- Flexible ducts follow product instructions, without compression, twisting or sagging that restricts the air path.
- Duct openings are protected from construction debris, and cleanliness is checked before commissioning.
- Access is provided to inspection and balancing components and filters where required by the design.
- Ductwork and insulation are coordinated with the ceiling, drainage and other services without obstructing access.
The ASHRAE chapter on duct construction emphasises installation instructions, system sealing and correct support for flexible ducts. Testing requirements and acceptance criteria follow the approved specifications. No single air velocity guarantees quiet operation along every route.
Can ordinary HVAC ductwork be used for smoke extraction?
Do not substitute ordinary HVAC ductwork for a smoke extraction system without specialist design and approval. The application, testing and classification requirements, components, joints, supports and penetrations determine the acceptable project solution.
There is no universal fire resistance duration, such as 120 minutes, or fixed air velocity that suits every building. An individual product classification does not establish the performance of the complete installed system. This page addresses HVAC air distribution; smoke systems require separate design and specifications.
What should you request at ductwork handover?
- As-built route and size drawings, showing components that require access.
- Material, insulation and classification documents matching the specifications.
- Required inspection and test results, including recorded issues and how they were resolved.
- An airflow and balancing report where required by the project, rather than a general statement that cooling is good.
- Care instructions for components and resealing any section opened later.
These items concern the air distribution system. The complete AC installation sequence is explained in concealed AC installation stages, testing and handover, while filter care and routine inspection are covered in the maintenance guide.
For a project assessment and coordination of the air distribution system with the unit, ceiling and other works, see our Concealed AC Design and Installation Service.