Computer Room Air Conditioning Systems (CRAC Units) – Precision Control for Data Center Environments

crac unit server room
Systems are considered CRAC Units (Computer Room Air Conditioning) the standard solution for cooling server rooms and data centers, fundamentally different from conventional air conditioning systems in terms of precision control, high reliability, and continuous response to fluctuating thermal loads.
Who is this service for?
CRAC solutions are specifically developed for:
data center
Server Rooms
server room inside a hospital or government facility
Data Centers
Network Operations Center
Telecommunications and Network Rooms
server room
Banks and Financial Institutions
network room
Hospitals and Government Entities
IT infrastructure room
UPS Room

These systems are designed to simultaneously control:

Temperature with high precision
To maintain a stable temperature within the recommended range for server rooms without fluctuations that could affect equipment performance.
Humidity Level
Controlling humidity within safe limits to prevent condensation or static electricity that could damage servers.
Uniform Air Distribution Within the Room
Directing cold air evenly to server inlets to ensure uniform cooling and prevent the formation of hot spots.
In alignment with the operational requirements of servers and sensitive network systems, following best practices adopted by leading global companies such as Trane, Carrier, and SKM.

Free engineering consultation before pricing

How do CRAC unit systems operate inside server rooms?

The CRAC Unit (Computer Room Air Conditioning) is a precision cooling system specifically designed to handle high and continuous thermal loads generated by servers and networking equipment, while maintaining a stable operating environment without sudden fluctuations.

It operates on the principle of continuous and precise cooling, rather than the intermittent operation commonly used in conventional air conditioning systems.
Operating Mechanism (Simplified Engineering Approach)
Hot Air Return
Hot air discharged from the servers is drawn through dedicated return inlets, typically from the upper or rear sections of the server room.
Air Treatment Inside the CRAC Unit
Lowering the air temperature, controlling humidity levels, and filtering the air from fine particles
Cold Air Redistribution
Cold air is recirculated in a controlled and uniform manner through raised floors or dedicated distribution ducts.
Continuous Control and Immediate Response
CRAC systems rely on precise sensors that continuously monitor temperature and humidity around the clock, automatically adjusting performance as needed.
Why is this system different?
According to the standards of leading global companies such as Trane and Carrier, CRAC systems are characterized by:

United’s Methodology in Designing and Implementing Computer Room Air Conditioning (CRAC Units)

At United HVAC, CRAC systems are not treated as standalone units, but as integrated engineering solutions that begin with load analysis and conclude with fully documented, commission-ready handover.
We follow a clear execution methodology tailored to server room and data center projects, where precision, reliability, and operational continuity are critical factors.
01
Engineering Analysis of Thermal Loads
  • Assessment of heat density generated by servers and equipment.
  • Analysis of load distribution within the room (Static / Dynamic Load).
  • Consideration of future expansions and redundancy requirements.
02
Cooling System and Air Distribution Design
  • Selection of the appropriate system type (CRAC / CRAH / integration with a raised floor).
  • Designing airflow paths to prevent hot spots.
  • Setting temperature and humidity control setpoints in accordance with operational standards.
03
Equipment Selection and Technical Specifications
  • Selection of approved CRAC units based on the project capacity.
  • Defining the control type, efficiency level, and continuous operation requirements.
  • Aligning specifications with the consultant’s and owner’s requirements.
04
Engineering Execution and Installation
  • Execution strictly in accordance with approved drawings, without temporary solutions.
  • Precise adjustment of air paths and connections.
  • Full coordination with electrical systems and monitoring systems.
05
Testing, Commissioning, and Handover
  • Testing & Commissioning تحت الأحمال التشغيلية.
  • Adjusting temperature and humidity control settings.
  • Providing clear technical and operational reports to the owner.
05
Why is this methodology important for the client?
  • Facilitating solution approval by the consultant or technical management
  • Reducing long-term operational risks
  • Ensuring the stability of the critical server room environment
icon dark color 72
1st
Why do clients trust us in implementing CRAC unit systems?

We don’t sell just a unit, but a fully integrated AC system built for long-term efficiency

Experience in Critical Environments
Implementation of CRAC systems for facilities operating 24/7, with a clear understanding of continuity requirements and zero-tolerance for downtime.
Commitment to Standards and Regulatory Requirements
Application of the Saudi Building Code, regulatory authority requirements, and approved data center standards.
Clear Execution Methodology
Design, implementation, and testing of systems according to approved procedures that ensure performance compliance prior to handover.
Focus on Operational Stability
Engineered solutions that ensure consistent performance, ease of operation and maintenance, even as loads vary over time.
crac unit skm f
What our clients say about us
Client Testimonials on HVAC Project Execution
0
Engineering consultation and technical report
0
Residential, commercial, and government projects
0
Maintenance contract
Quality and mastery of work and speed of response. They complete their work without being asked. The materials used are the best materials for air conditioning. They have an excellent technical staff, and all of this is thanks to God and then to Engineer Muhammad Abu Al-Baraa, a cheerful and respectful man, God willing, he is understanding and understands his work and responds to any comment. Thank you, Engineer, for the good treatment and high morals from you.
unnamed
Concealed ducted AC project
Send the air conditioning plan

Our certificates

Projects
Selected Completed CRAC Unit Projects

تفاصيلنا تصنع الفارق: خلف الأسقف الأنيقة، تكمن هندسة دقيقة بتصميم وتوزيع مثالي للهواء يمنحك برودة شاملة لكل زاوية بهدوء، لأننا نهتم بجودة الهواء الذي تتنفسه

Concealed ac in living room
Palaces and villas
Sports clubs
Sports clubs
Office air conditioning
Showroom and offices
Hotel air conditioning
Hotels, towers
shopping mall
Malls
Restaurant air conditioning
Restaurants, cafe shop
Warehouse air conditioning
Warehouses, factories
mosque
Mosques
Air conditioning of hospitals and health centers
Hospitals
Air conditioning of schools and universities
universities and schools
Chiller Carrier air conditioners
Government projects
We are trusted by more than 40 + government agencies and institutions
Integrated HVAC services
Study, design and installation of all HVAC systems،
Unique solutions and services designed specifically for our customers
VAT
310098477500003
CR: 1010499033
Certified and certified by
Saudi Business Center
0000145510
Secure payment channels
Secure payment through
reliable channels that protect our customers ' data
Subscribe to our newsletter
We are trusted by more than 40 + government agencies and institutions